Experimental Investigation of Flexible Staggered Baffles and Their Effect on Hydraulic Jump Characteristics

Document Type : Research Article

Authors
1 Shahid Chamran University of Ahvaz Faculty of Water and environment Engineering
2 shahid chamran university of Ahvaz
3 Shahid Chamran University of Ahvaz
10.30482/jhyd.2026.603431.1790
Abstract
Introduction
Type I stilling basin is one of the energy dissipating structures that have been constructed in irrigation and drainage networks so far. Reasons such as increasing the inflow characteristics or decreasing the level of the tailwater, as well as changes in network operation, cause the kinetic energy of the flow inside the basin to not be dissipated and part of the jump is shifted outside the basin, which leads river bed scour and formation of surface waves in the downstream channel. During the past three decades, many studies have been conducted on the use of installing rigid baffles (such as concrete blocks) or different shape and size of rigid roughness on the basin floor to increase dissipation energy, shortened the basin length and decrease the required downstream flow depth for jump to occur. Therefore, for existing type I basins, the practical solution is to implement baffles on the bed, which leads to increased energy consumption. Rigid basin requires the inflow water to be stop for several weeks which in many cases it is not possible to interrupted the flow. Thus, In this study, flexible baffles, which are easy, fast and less expensive to install, have been introduced and their effect on Hydraulic Jump Characteristics has been investigated

Material and methods
The present research was conducted in the Physical Models Laboratory of the Faculty of Water and Environmental Engineering, Shahid Chamran University of Ahvaz, in a flume with a length of 8 meters, height and width of 60 and 70 centimeters, respectively. Figure (1) shows the longitudinal cross-section of the aforementioned flume. The water flow from the underground reservoir is supplied by a centrifugal pump with a maximum capacity of 70 liters per second, which is measured by an electromagnetic flowmeter with an accuracy of ± 0.01 liters per second. The flow rate is controlled by a valve installed in the path of the inlet pipe to the flume. Before entering the flume, the flow enters a calming pond, at the end of which a 60-centimeter-high, peak-shaped spillway with a width of the flume is installed. Upstream of the spillway, a graduated tape with an accuracy of one millimeter and at a distance of four times the maximum water head from the crest of the spillway is installed, from which the water head of the flowing flow is read. A hinged gate is used at the end of the flume to adjust the required backwater depth, and to force the jump to start downstream of the spillway. The rigid baffles with the characteristics as shown in Table 2 was selected. Then, the dimensions of these barriers were determined as a factor of the flow depth at the spillway’s toe (Y1≈3 cm), for the highest tested discharge (Q≈70 L/S). Therefore, the width (Wb) and length (Lb) of the barriers were chosen to be 6 cm (Wb/Y1=2) and 9 cm (Lb/Y1=3), respectively. These baffles were installed with two types of scattered arrangement (Z1 and Z2) as show in Fig.3 and tested under different flow conditions.
Results
The main results from this study are: The secondary depth of the hydraulic jump in the Z1 and Z2 configurations has decreased by about 47 and 34 percent, respectively, compared to the classical basin. The hydraulic jump length in the Z1 and Z2 configurations has decreased by about 52 and 38 percent, respectively, compared to the classical basin. The energy consumption in the Z1 and Z2 configurations has increased by about 16 and 12 percent, respectively, compared to the classical basin. The Z1 configuration has shown better performance in terms of improving the main characteristics of the hydraulic jump, such as the secondary depth and hydraulic jump length, which have decreased by about 20 and 23 percent, respectively, and also with an increase of about 4 percent more energy consumption, compared to the Z2 configuration. Although the results of this study have shown a very good effect on the performance of hydraulic jump characteristics in classical stilling ponds by installing flexible barriers, it is recommended that further studies be conducted on larger scales than the present study to use the results of this study in practice (field work).
Keywords
Subjects