<ArticleTitle>Discharge-Level laboratory investigation of the flow passing through the composite structure of sharp crested triangular with multiple orifices</ArticleTitle>
<VernacularTitle>بررسی آزمایشگاهی دبی-اشل جریان عبوری از سازه ترکیبی سرریز لبه تیز مثلثی با روزنه چندگانه</VernacularTitle>
			<FirstPage>37</FirstPage>
			<LastPage>53</LastPage>
			<ELocationID EIdType="pii">190060</ELocationID>
			
<ELocationID EIdType="doi">10.30482/jhyd.2023.413734.1671</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>سیده نگار</FirstName>
					<LastName>سادات احمدی</LastName>
<Affiliation>فارغ التحصیل کارشناسی ارشد، گروه سازه های آبی دانشکده مهندسی آب و محیط زیست دانشگاه شهید چمران اهواز</Affiliation>
<Identifier Source="ORCID">0009-0002-5051-714x</Identifier>

</Author>
<Author>
					<FirstName>مهدی</FirstName>
					<LastName>زینی وند</LastName>
<Affiliation>استادیار گروه سازه های آبی، دانشکده مهندسی آب و محیط زیست، دانشگاه شهید چمران اهواز، اهواز، ایران</Affiliation>
<Identifier Source="ORCID">0000-0002-2931-2118</Identifier>

</Author>
<Author>
					<FirstName>مهدی</FirstName>
					<LastName>قمشی</LastName>
<Affiliation>استاد گروه سازه‌های آبی، دانشکده مهندسی آب و محیط زیست، دانشگاه شهید چمران اهواز، اهواز، ایران.</Affiliation>
<Identifier Source="ORCID">0000-0002-8361-1645</Identifier>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2023</Year>
					<Month>10</Month>
					<Day>08</Day>
				</PubDate>
			</History>
		<Abstract>Structures such as weirs and orifices, their main function is to measure the flow rate and regulate the water level. The combination of weir and orifice structure has been noticed in the last decade. When there is a flood, by placing several orifices with a certain number and dimensions in the lower part of this weir, it is possible to pass more discharge. In this laboratory research, the percentage increase in discharge rate and changes in water flow in each of the models designed by changing the number and dimensions of orifices in the sharp-crest triangular weir with multiple orifices have been estimated. In the present research 19 weirs with square orifices were designed in five cases from one to five orifices and in dimensions of two to five centimeters and one weir without an orifice was designed as a control test. The results of this laboratory research showed that for a fixed control level, while the same level remains constant, due to the change in the number of orifices or the dimensions of the orifices, the flow discharge has increased. The results of examining the amount of flow rate changes (difference between the flow discharge resulting from the overflow-orifice test and the flow discharge resulting from the overflow without orifice) have shown that in each test sample, with the increase of each orifice created on average by two liters per second and per one increase of every one centimeter in the size of the orifice adds 2.3 liters per second to the water flow discharge. In the best case, for a combined overflow with a change in the size of the orifice from three to four centimeters in a fixed control level, it has the highest percentage of passing flow and is 57%. On the other hand, in the best case, by increasing the number of orifices from three to four apertures in a fixed control level, this percentage increase has reached approximately 42%, and it shows the superiority of these two combined models compared to other tested models.</Abstract>
			<OtherAbstract Language="FA">ا در این تحقیق آزمایشگاهی میزان درصد افزایش دبی عبوری و تغییرات آبگذری در هر یک از مدل‌های طراحی شده با تغییر تعداد و ابعاد روزنه در سرریز مثلثی لبه تیز با روزنه چندگانه برآورد گردیده است. در تحقیق حاضر، 19 سرریز با روزنه‌ی مربع شکل در پنج حالت از یک الی پنج روزنه و در ابعاد دو الی پنج سانتی‌متر و یک سرریز بدون روزنه تحت عنوان آزمایش شاهد طراحی گردید. نتایج این تحقیق آزمایشگاهی نشان داد که‌ به ازای یک تراز شاهد ثابت، ضمن اینکه همان تراز ثابت بماند با توجه به تغییر تعداد روزنه و یا ابعاد روزنه، میزان دبی آبگذری افزایش یافته است. نتایج حاصل از بررسی میزان تغییرات دبی ( تفاضل دبی حاصل از آزمایش سرریز-روزنه و دبی حاصل از سرریز بدون روزنه) نشان داده است که در هر اشل شاهد ثابت، با افزایش هر یک روزنه ایجاد شده بطور متوسط به میزان دو لیتربرثانیه و به ازای افزایش هر یک سانتی‌متر به ابعاد روزنه به میزان 3/2 لیتربرثانیه به مقادیر دبی آبگذری افزوده می‌گردد. در بهترین حالت برای سرریز ترکیبی با تغییر ابعاد روزنه از سه به چهار سانتی‌متر در یک اشل ثابت، بیشترین درصد دبی عبوری و به میزان 57درصد داشته است. از طرفی در بهترین حالت با افزایش تعداد روزنه از سه به چهار روزنه در یک اشل ثابت، این میزان درصد افزایش به طور تقریبی به 42درصد رسیده است و نشان از برتری این دو مدل ترکیبی نسبت به سایر مدل‌های مورد آزمایش بوده است.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">سرریز لبه تیز مثلثی</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">روزنه چندگانه</Param>